THE BEST SIDE OF DP50RB

The best Side of Dp50rb

The best Side of Dp50rb

Blog Article

Support 4D probe; understand the probe by way of the ID code; change the 4D generate signal by means of the  electrical relay to help make the 4D probe function Usually. four.2.two Primary board The main board could possibly be divided into two areas: front-conclude of the primary board and again-conclusion of the principle board.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

Will not use any cables besides the cables supplied Together with the unit by Mindray. 3. Utilize the cable delivered with this system to attach the printer. Other cables may perhaps end in electrical shock. Website page 15: Mechanical Basic safety

The user just isn't allowed to open up the covers and panel on the technique, neither NOTE: gadget disassemble is allowed. To make sure the method efficiency and security, only Mindray engineers or engineers authorized by Mindray can accomplish servicing.

Explore superior diagnostic information via prolonged watch of your anatomical structure on all convex probes.

Reduce off cable ties connecting the principle unit over the Screen by diagonal chopping pliers, and then pull out the corresponding cable plugs.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Mindray’s new technology of black & white ultrasound method, DP-fifty Qualified, is provided with Highly developed imaging systems letting deeper penetration and more rapidly picture acquisition with higher resolution.

Be aware: Before uploading the log, make certain the ultrasound procedure continues to be connected to network, normally, the procedure might alert “couldn't connect with server” The server (smtp.

iZoom™ enables correct viewing of image from distance iWorks™ Protocol assists standardize workflow and cut down Examination moments

NOTE: To the watch, the brightness adjustment will come in advance of contrast. Following readjusting the check’s distinction and brightness, modify all preset and peripheral settings.

Most 4 periods tasking for a person transmitted beam, resulting in great time resolution and better frame price.

Immediately after changing the CPU module, important file need to be created Again in accordance with the new MAC handle and composed into HDD from the equipment. Or else, the configuration perform from the product or service might be shed. Just after taking away the CPU module, Take out panhead screws with washers (twelve M3X6) set on the most crucial device box, you may take off the board. Web page 118 Figure eight-29 Disassemble the Control Panel Assembly (one) Hold the upper fringe of user interface assembly, and open up the user interface. Determine 8-thirty Disassemble the Control Panel Assembly (2) After eliminating one particular countersunk head self-tapping screw PT3X10 mounted within the user interface and get out the plug with the keyboard and the key device connecting cables, you could potentially take away the user interface assembly.

Performance Examination 5.5.1 Exam Process Resolution Detection depth Geometric Posture Precision Blackout place examination Record the exam photos five.5.two Take a look at Material The impression employed here is just for reference, follow the image effect in the real NOTE: situation. Necessities: Display screen: established the contrast and brightness with the scientific application price (or perhaps the default standing) Operation environment: dark home, simulating the scientific application environment. Site 76 In affliction which the transverse resolution screening targets are horizontally displayed, record the small Dp50rb length of two targets which might be Evidently regarded. Repeat the Procedure above for your transverse resolution tests targets at other depths. As proven in figure below. Axial resolution ... Web page seventy seven When using the convex probe, hold the transverse resolution tests targets to NOTE: be shown close to the midline. When using a linear probe with steer functionality, usually do not activate the steer purpose when conduct the transverse resolution test. Zoom in the region the place the targets Positioned if essential. The diameter in the focus on stage at a certain depth is equal on the transverse resolution in the depth. Web site seventy eight five.

A wise new form, enhanced mobility and effortless operation make DP-50 well suited for all medical options.

five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Test Phase: Do adjustments as just how in tests the most depth. Document the distance by 20mm Just about every section to the longitudinal targets line using the measurement caliper; Decide on the worth with the greatest mistake (to 20mm), determine the precision utilizing the formulation beneath The measurement caliper needs to be positioned in the higher edge of the goal, Observe:... Web site seventy nine Transverse geometric positioning precision  Check Move: Cover the scan area with the phantom with drinking water or pair gel, gently Get in touch with the probe While using the scan area Modify the depth, producing the transverse targets to be shown while in the graphic. Modify the main target level being posited beside the transverse targets (the conventional is not very clear) Adjust parameters like gain, TGC, making Each individual transverse targets for being Plainly displayed. Page eighty 5.five.two.four Blackout Location Examination Action: Cover the scan floor in the phantom with h2o or couple gel, Carefully Make contact with the probe with the scan area Modify the depth at a lower price, and set the focus at the nearest destination to the scan area. Minimize the worth of parameters like AP, Acquire right up until the qualifications noise just could be found. Website page eighty one: Computer software Enhance And Maintenance